wns automatic oil fired steam boiler

wns automatic oil fired steam boiler

Steam Gas Gas Desulfurization to achieve excellent results steam oven gas steam oven must sample tests, the thermal conductivity was measured quality of appearance, flash point, viscosity, acid, water, and carbon residue, provided with heat transfer fluids plant proof mass It is consistent with the book, but also provide the basis for future changes in the operation of medium quality monitoring. Means passing the tests of the gas-steam heat transfer fluids using pumps to transfer fluids within the furnace and the injection of hot expander. When pumps heat transfer fluid to the injection system, should check again the furnace, heating equipment, piping system drain valve, drain valve is closed, in order to avoid loss of heat transfer fluids. While the exhaust pipe and the valve opening on the furnace one by one, to exclude air, until a closed gas steam flows. It stops when the oil level gauge appears on the expander injection heat transfer fluids, and then start the circulation pump, for circulating cold. Existing gas steam oven dry dust, do not meet wet desulphurization process of flue gas CWS humidity, water vapor in the flue gas as coal-water slurry up to 36%, some as high as 40% or more water content of coal-water slurry, If we consider only the dust and sulfur dioxide that is not enough. Arts gas wns automatic fired steam boiler company after multi-party experts to study, test, develop a dusting product, the successful use of coal-water slurry plenty of water in the flue gas as a carrier, by cooling, reducing condensation, dust and sulfur dioxide capture down, to achieve excellent results gas desulfurization steam oven. The effect of dust reaching the user's satisfaction. Gas welding gas steam oven must be operated by welders holding boiler and pressure vessel certification of welders. Welding dimensions meet the design drawings and process documents, bead height is not less than the base material, the base material with a smooth transition. Gas fuel gas steam oven weld and heat affected zone no cracks, holes, craters and slag. Weld undercut hole deeper than 0.5mm, the total length (the sum of both) is not more than 1/4 of the circumference of the tube, and not more than 40mm. Construction of gas steam oven strict compliance with welding procedures and other relevant standards and regulations, and make construction records welded to record the record.

Combustion gas treatment and a malfunction due to gas boiler burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Gas Burner fails, the action bar ignition misfire following five: Clear, renewal, adjust the distance, change and switching transformer. Second, the gas boiler the ignition spark rod misfiring but the reasons: 1, the disk space ventilation carbon cyclone is blocked, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Burner gas treatment increased noise: ① the check valve in the oil line is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

Multiple protection devices take you through the oil wns automatic fired steam boiler oil steam boiler water level protection, boiler water level gauge plate supporting one to two, should always be compared with each other, findings indicate inconsistency shall be corrected immediately. Class water level should be flushed, to determine their true level. While the water level comes electrode rod can accurately capture level signal to an alarm or a pump control. Steam pressure protection, the pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switches, automatic control chain protection or other control lines. Using pressure controllers and electrical contacts, the vapor pressure can overpressure alarm; single adjustable pressure controller or dual fire burning fire the actual operating pressure. Safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. Flame protection, having imported burner flame protection means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged of residual internal combustible gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. Self-locking power protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.

To continue to improve ambient air quality, to meet the people's growing need for beautiful ecological environment, Zaozhuang City, Shandong Province issued the latest "blue sky Zaozhuang City win the Battle of the operational plan (2018-2020 years)" (the "Program"). "Plan" put forward, built-up urban areas to carry out experimental work, to carry out large-scale coal-fired units off white wet flue gas treatment. The main objective of the "program" is that after three years of efforts, the total emissions of major air pollutants significantly reduce greenhouse gas emissions reduction synergies, significantly reduced the concentration of PM2.5, significantly reduced the number of days of heavy pollution, ambient air quality improved significantly, the people of the blue sky well-being significantly enhanced. By 2020, the city of sulfur dioxide, nitrogen oxide emissions are lower than 27% in 2015, the ozone concentration significantly increasing trend containment; of PM2.5, PM10年平均浓度分别控制在 57 mg / m, 91 [mu] g / m or less, sulfur dioxide, nitrogen oxides average concentration continued to improve air quality not less than 62%, more than the number of days of severe contamination and declining.

1, adjusting the industrial structure and layout, increase the elimination of backward production capacity and excess generated Yajian efforts; continued implementation of the regulation "scattered pollution" enterprise, and resolutely put an end to, "scattered dirt" project and has been banned "dirty scattered" Project resurgence after migration.

2, continued implementation of the total coal consumption control, by 2020, the city's total coal consumption control in less than 22.43 million tons, out of shutting down Daly environmental protection, energy consumption, safety and other 300,000 kilowatts of coal-fired units of non-compliance ; strongly promote the comprehensive improvement of coal-fired boilers, in 2018 the city built the region basically eliminated tea furnace, stove and other operating coal-fired facilities, a ban on new 35 steam tons / hour of coal-fired boilers, 65 tons of steam / hour or more coal-fired Upon completion of the boiler on the ultra-low emission, energy saving completed; low nitrogen gas boiler is substantially complete transformation.

3, vigorously promote clean energy heating, accelerate the pace of construction of natural gas to clear the system infrastructure, new natural gas for coal substitution when the priority of urban residents and winter heating, to achieve "by reducing coal gas", "coal to gas" adhere to the " gas will change. "

1, the full implementation of pollution permits management to achieve a comprehensive industrial pollution discharge standards. Accelerate the granting of emission permits, continue to promote the transformation of standard industrial pollution sources.

2, vigorously promote cleaner production. Of development zones, industrial parks, high-tech zones of concentration and control, compliance deadline conduct reform, reduce pollution industrial zone.

wns automatic oil fired steam boiler Related Information

Automatic Wns Gas Fired Condensing Steam Boilers

Automatic Wns Oil Gas Fired Steam Boiler. Gas or Oil Fired Steam Boiler-Steam boiler--Yuanda . Overview. WNS gas & oil fired steam boiler is a kind of safe and high efficiency heating equipment from Yuanda with full automatic control system, It can also be regarded as fire tube boiler, packaged boiler, three pass design boiler and eco-friendly boiler.

Get a Quote

2018 Latest ISO Certificate Wns Gas/Oil Fired Steam

2018 Latest ISO Certificate Wns Gas/Oil Fired Steam Boiler 1. Introduction of 2016 Latest ISO Certificate Wns Gas/Oil Fired Steam Boiler Automatic WNS boiler is a kind of horizontal, three-pass, wet back, fire tube boiler. Wet back means the back of furnace is surrounded by water, then the temperature of tube plate will be much lower.

Get a Quote

wns automatic gas boiler - kamerunschafe-bethen.de

WNS Series Gas Fired Packaged Steam Boiler - Oil/Gas Zhongding WNS series gas fired packaged steam boiler is jointly designed by Xian Jiaotong University, it is a kind of safe and high efficiency heating equipment with full automatic control system.

Get a Quote

oil fired boiler,gas fired boiler,gas steam boiler,oil

Our WNS type oil gas fired boiler is a horizontal fire tube boiler.The second and third return smoke pipes are washed by the high temperature flue gas, 10 Tph Gas Oil Fired Industrial Steam Boiler Automatic Running For Rice Mill Paper Mill;

Get a Quote

Automatic Wns Steam Kettle Boiler - kurpark-turnier.de

Coal fired steam boiler is horizontal style, low pressure, single drum, fire and water tube structure, chain grate steam boiler WNS series oil gas fired boiler is a safe and high efficiency (98%) heating equipment with high automation, fast assemble boiler with flue gas three pass and wet back structure, widely used for industrial production.

Get a Quote

full automatic gas water boiler oil fired boiler for sale

2019-3-31 · WNS Automatic Oil & Gas-fired Boiler WNS series Oil & Gas-fired boiler is horizontal internal combustion three return full wet back type fire tube boiler(<1t/h center back . The requirements in the standard for gas-fired heating and hot water combi-boiler are hardware of fully automatic test system for gas-fired Full -text

Get a Quote

China Wns Gas Oil Fired Steam Boiler 15t/H - China

China Wns Gas Oil Fired Steam Boiler 15t/H, Find details about China Gas Boiler, Steam Boiler from Wns Gas Oil Fired Steam Boiler 15t/H - Wuxi Zozen Boilers Co., Ltd.

Get a Quote

Gas/lpg fired boiler,Oil boiler,Packaged gas oil boiler

2020-4-8 · Gas-fired (oil-fired) Boiler 0.1 - 50Ton/hr Gas-fired(Oil-fired) boiler, horizontal fire tube boiler, shell boiler with three pass design. Large combustion chamber and world-known burner, making higher heating efficiency and low heat loss.

Get a Quote

WNS Series Crude Oil Fired Wet Back Steam Boiler -

WNS series crude oil fired wet back steam boiler is widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital

Get a Quote

full automatic gas water boiler oil fired boiler for sale

2019-3-31 · WNS Automatic Oil & Gas-fired Boiler WNS series Oil & Gas-fired boiler is horizontal internal combustion three return full wet back type fire tube boiler(<1t/h center back . The requirements in the standard for gas-fired heating and hot water combi-boiler are hardware of fully automatic test system for gas-fired Full -text

Get a Quote

wns automatic gas boiler - kamerunschafe-bethen.de

WNS Series Gas Fired Packaged Steam Boiler - Oil/Gas Zhongding WNS series gas fired packaged steam boiler is jointly designed by Xian Jiaotong University, it is a kind of safe and high efficiency heating equipment with full automatic control system.

Get a Quote

Yinchen New WNS oil Gas Fired Full-automatic Steam

Hot PLC Automatic Control 6 ton Diesel Oil Gas Fired Industrial Steam Boiler WNS series gas/oil fired steam boiler is horizontal three pass fire tube wet back full automatic steam boiler. It normally suitable for 500kg to 20ton/h capacity, use all kinds of gas and oil fuels,such as natural gas, lpg,lng,cng,city gas,biogas, diesel oil,heavy oil.

Get a Quote

Steam Boiler WNS - bosch-industrial-asean.com

Fire tube Steam Boiler Bosch Packaged Shell Boiler. WNS Series Oil &Gas-fired Steam Boiler applies advanced industrial boiler safety control system, PLC design and independent interlock protection system with intelligent and convenient Boiler operation interface.

Get a Quote

WNS Series gas oil Steam Boiler,gas fired steam

2019-7-18 · The WNS series gas oil steam boiler is three-return fired tube steam boiler with wet back structure. Sitong boiler manufacture and export multiple kinds of boilers worldwide. we popular sales the steam boiler, gas oil fired boiler, thermal oil boiler, electric heating boiler, hot water boiler, etc.

Get a Quote

China Steam Boiler, Steam Boiler Manufacturers,

China Steam Boiler manufacturers - Select 2020 high quality Steam Boiler products in best price from certified Chinese Boiler manufacturers, Gas Boiler suppliers, wholesalers and factory on

Get a Quote

Do You Want To Get An Exclusive Project Plan ?

7 * 24 * 365 endless service, click the button to provide you with professional and fast solutions at any time

Scroll to Top